魅族SEm8和魅族REM8有什么区别

魅族SEm8和魅族REM8有什么区别,第1张

SE是老版的升级版 系统更加稳定

RE版简单来说就是魅族原厂翻新机

不过质量可以放心 只是换了个新外壳 重新上市 RE版物美价廉 值得购买

SE 版 也很好

英文,凑合着看吧

摘自wiki

(http://en.wikipedia.org/wiki/Electron_Microscope)

Electron microscope

From Wikipedia, the free encyclopedia

(Redirected from Electron Microscope)

Jump to: navigation, search

This article does not cite any references or sources.

Please help improve this article by adding citations to reliable sources. (help, get involved!)

Any material not supported by sources may be challenged and removed at any time. This article has been tagged since November 2006.

The electron microscope is a type of microscope that uses electrons to create an image of the target. It has much higher magnification and resolving power than a normal light microscope, up to two million times, allowing it to see smaller objects and details.

Contents [hide]

1 History

2 Electron microscope manufacturers

3 Types

3.1 Transmission Electron Microscope (TEM)

3.2 Scanning Electron Microscope (SEM)

3.3 Reflection Electron Microscope (REM)

3.4 Scanning Transmission Electron Microscope (STEM)

4 Sample Preparation

5 Disadvantages

6 See also

7 External links

8 References

8.1 Archives

[edit] History

A transmission electron microscope.

An image of an ant from a scanning electron microscopeThe first electron microscope prototype was built in 1932 by the German engineers Ernst Ruska and Max Knoll. It was based on the ideas and discoveries of French physicist Louis de Broglie. Although it was primitive and not fit for practical use, the instrument was still capable of magnifying objects by four hundred times.

Reinhold Rudenberg, the research director of Siemens, had patented the electron microscope in 1931, although Siemens was doing no research on electron microscopes at that time. In 1937 Siemens began developing the electron microscope, funding Ruska and Bodo von Borries to develop the instrument. Siemens also employed Ruska's brother Helmut to work on applications, particularly with biological materials. [1][2]

Siemens produced the first commercial TEM in 1939, but the first practical electron microscope was built at the University of Toronto in 1938, by Eli Franklin Burton and students Cecil Hall, James Hillier and Albert Prebus.[3]

Although modern electron microscopes can magnify objects up to two million times, they are still based upon Ruska's prototype and his correlation between wavelength and resolution. The electron microscope is an integral part of many laboratories. Researchers use it to examine biological materials (such as microorganisms and cells), a variety of large molecules, medical biopsy samples, metals and crystalline structures, and the characteristics of various surfaces.

[edit] Electron microscope manufacturers

Major manufacturers include:

Delong Group

FEI Company - USA (formerly a division of Philips Electronics)

FOCUS GmbH - Germany

Hitachi - Japan

JEOL, Inc. - Japan (Japan Electro Optics Laboratory)

TESCAN - EU

Carl Zeiss NTS GmbH

[edit] Types

[edit] Transmission Electron Microscope (TEM)

Main article: Transmission electron microscopy

The original form of electron microscopy, Transmission electron microscopy (TEM) involves a high voltage electron beam emitted by a cathode and formed by magnetic lenses. The electron beam that has been partially transmitted through the very thin (and so semitransparent for electrons) specimen carries information about the inner structure of the specimen. The spatial variation in this information (the "image") is then magnified by a series of magnetic lenses until it is recorded by hitting a fluorescent screen, photographic plate, or light sensitive sensor such as a CCD (charge-coupled device) camera. The image detected by the CCD may be displayed in real time on a monitor or computer.

Resolution of the high-resolution TEM (HRTEM) is limited by spherical aberration and chromatic aberration, but a new generation of aberration correctors has been able to overcome spherical aberration. Software correction of spherical aberration has allowed the production of images with sufficient resolution to show carbon atoms in diamond separated by only 0.89 ångström (89 picometers) and atoms in silicon at 0.78 ångström (78 picometers) at magnifications of 50 million times. The ability to determine the positions of atoms within materials has made the HRTEM an indispensable tool for nano-technologies research and development in many fields, including heterogeneous catalysis and the development of semiconductor devices for electronics and photonics.

Transmission electron microscopes produce two-dimensional images.

[edit] Scanning Electron Microscope (SEM)

Main article: Scanning Electron Microscope

Unlike the TEM, where electrons are detected by beam transmission, the Scanning Electron Microscope (SEM)[4] produces images by detecting secondary electrons which are emitted from the surface due to excitation by the primary electron beam. In the SEM, the electron beam is rastered across the sample, with detectors building up an image by mapping the detected signals with beam position.

Generally, the TEM resolution is about an order of magnitude better than the SEM resolution, however, because the SEM image relies on surface processes rather than transmission it is able to image bulk samples and has a much greater depth of view, and so can produce images that are a good representation of the 3D structure of the sample.

[edit] Reflection Electron Microscope (REM)

In addition there is a Reflection Electron Microscope (REM). Like TEM, this technique involves electron beams incident on a surface, but instead of using the transmission (TEM) or secondary electrons (SEM), the reflected beam is detected. This technique is typically coupled with Reflection High Energy Electron Diffraction and Reflection high-energy loss spectrum (RHELS). Another variation is Spin-Polarized Low-Energy Electron Microscopy (SPLEEM), which is used for looking at the microstructure of magnetic domains [1].

[edit] Scanning Transmission Electron Microscope (STEM)

main article: Scanning Transmission Electron Microscopy STEM

[edit] Sample Preparation

Materials to be viewed under an electron microscope may require processing to produce a suitable sample. The technique required varies depending on the specimen and the analysis required:

Cryofixation - freezing a specimen so rapidly, to liquid nitrogen or even liquid helium temperatures, that the water forms vitreous (non-crystalline) ice. This preserves the specimen in a snapshot of its solution state. An entire field called cryo-electron microscopy has branched from this technique. With the development of cryo-electron microscopy of vitreous sections (CEMOVIS), it is now possible to observe virtually any biological specimen close to its native state.

Fixation - preserving the sample to make it more realistic. Glutaraldehyde - for hardening - and osmium tetroxide - which stains lipids black - are used.

Dehydration - replacing water with organic solvents such as ethanol or acetone.

Embedding - infiltration of the tissue with a resin such as araldite or epoxy for sectioning.

Sectioning - produces thin slices of specimen, semitransparent to electrons. These can be cut on an ultramicrotome with a diamond knife to produce very thin slices. Glass knives are also used because they can be made in the lab and are much cheaper.

Staining - uses heavy metals such as lead, uranium or tungsten to scatter imaging electrons and thus give contrast between different structures, since many (especially biological) materials are nearly "transparent" to electrons (weak phase objects). In biology, specimens are usually stained "en bloc" before embedding and also later stained directly after sectioning by brief exposure to aqueous (or alcoholic) solutions of the heavy metal stains.

Freeze-fracture or freeze-etch - a preparation method particularly useful for examining lipid membranes and their incorporated proteins in "face on" view. The fresh tissue or cell suspension is frozen rapidly (cryofixed), then fractured by simply breaking or by using a microtome while maintained at liquid nitrogen temperature. The cold fractured surface (sometimes "etched" by increasing the temperature to about -100°C for several minutes to let some ice sublime) is then shadowed with evaporated platinum or gold at an average angle of 45° in a high vacuum evaporator. A second coat of carbon, evaporated perpendicular to the average surface plane is often performed to improve stability of the replica coating. The specimen is returned to room temperature and pressure, then the extremely fragile "pre-shadowed" metal replica of the fracture surface is released from the underlying biological material by careful chemical digestion with acids, hypochlorite solution or SDS detergent. The still-floating replica is thoroughly washed from residual chemicals, carefully fished up on EM grids, dried then viewed in the TEM.

Ion Beam Milling - thins samples until they are transparent to electrons by firing ions (typically argon) at the surface from an angle and sputtering material from the surface. A subclass of this is Focused ion beam milling, where gallium ions are used to produce an electron transparent membrane in a specific region of the sample, for example through a device within a microprocessor. Ion beam milling may also be used for cross-section polishing prior to SEM analysis of materials that are difficult to prepare using mechanical polishing.

Conductive Coating - An ultrathin coating of electrically-conducting material, deposited either by high vacuum evaporation or by low vacuum sputter coating of the sample. This is done to prevent the accumulation of static electric fields at the specimen due to the electron irradiation required during imaging. Such coatings include gold, gold/palladium, platinum, tungsten, graphite etc. and are especially important for the study of specimens with the scanning electron microscope.

[edit] Disadvantages

Pseudocolored SEM image of the feeding basket of Antarctic krill. Real electron microscope images do not carry any color information, they are greyscale. The first degree filter setae carry in v-form two rows of second degree setae, pointing towards the inside of the feeding basket. The purple ball is one micrometer in diameter. To display the total area of this fascinating structure one would have to tile 7500 times this image.Electron microscopes are expensive to buy and maintain. They are dynamic rather than static in their operation: requiring extremely stable high-voltage supplies, extremely stable currents to each electromagnetic coil/lens, continuously-pumped high-/ultra-high-vacuum systems, and a cooling water supply circulation through the lenses and pumps. As they are very sensitive to vibration and external magnetic fields, microscopes aimed at achieving high resolutions must be housed in buildings (sometimes underground) with special services. Newer generations of TEM operating at lower voltages (around 5 kV) do not have stringent voltage supply, lens coil current, cooling water or vibration isolation requirements and as such are much less expensive to buy and far easier to install and maintain.

The samples have to be viewed in vacuum, as the molecules that make up air would scatter the electrons. Recent advances have allowed hydrated samples to be imaged using an environmental scanning electron microscope.

Scanning electron microscopes usually image conductive or semi-conductive materials best. Non-conductive materials can be imaged by an environmental scanning electron microscope. A common preparation technique is to coat the sample with a several-nanometer layer of conductive material, such as gold, from a sputtering machinehowever this process has the potential to disturb delicate samples.

The samples have to be prepared in many ways to give proper detail, which may result in artifacts purely the result of treatment. This gives the problem of distinguishing artifacts from material, particularly in biological samples. Scientists maintain that the results from various preparation techniques have been compared, and as there is no reason that they should all produce similar artifacts, it is therefore reasonable to believe that electron microscopy features correlate with living cells. In addition, higher-resolution work has been directly compared to results from X-ray crystallography, providing independent confirmation of the validity of this technique. Recent work performed on unfixated, vitrified specimens has also been performed, further confirming the validity of this technique.

[edit] See also

Wikibooks has more about this subject:

The Opensource Handbook of Nanoscience and NanotechnologyCategory:Electron microscope images

Field emission microscope

[edit] External links

Electron Microscopy Supplies - Ladd Research

Environmental Scanning Electron Microscope (ESEM)

X-ray element analysis in electron microscope - Information portal with X-ray microanalysis and EDX contents

http://www2.physics.utoronto.ca/overview/history/microsco/microscopy.htm (John H.L. Watson: VERY EARLY ELECTRON MICROSCOPY IN THE DEPARTMENT OF PHYSICS, THE UNIVERSITY OF TORONTO — A PERSONAL RECOLLECTION)

[edit] References

^ DH Kruger, P Schneck and HR Gelderblom (13). "Helmut Ruska and the visualisation of viruses" (in English). The Lancet 355 (9216): 1713-1717. DOI:10.1016/S0140-6736(00)02250-9.

^ Ernst Ruska (1986). Ernst Ruska Autobiography (English). Nobel Foundation. Retrieved on 2007-02-06.

^ MIT biography of Hillier

^ SCANNING ELECTRON MICROSCOPY 1928 - 1965

[edit] Archives

Rubin Borasky Electron Microscopy Collection, 1930-1988 Archives Center, National Museum of American History, Smithsonian Institution.

v • d • e Pathology

Anatomical pathology - Clinical Pathology - Experimental Pathology

Anatomical pathology

Surgical pathology | Cytopathology | Autopsy | Molecular pathology | Forensic Pathology | Dental pathology

Gross examination | Histopathology | Immunohistochemistry | Electron microscopy | Immunofluorescence | Fluorescent in situ hybridization

Clinical pathology

Clinical chemistry | Hematopathology | Transfusion medicine | Medical microbiology | Diagnostic immunology

Enzyme assay | Mass spectrometry | Chromatography | Flow cytometry | Blood banking | Microbiological culture | Serology

Retrieved from "http://en.wikipedia.org/wiki/Electron_microscope"

Categories: Articles lacking sources from November 2006 | All articles lacking sources | Anatomical pathology | Electron | Microscopes


欢迎分享,转载请注明来源:夏雨云

原文地址:https://www.xiayuyun.com/zonghe/161680.html

(0)
打赏 微信扫一扫微信扫一扫 支付宝扫一扫支付宝扫一扫
上一篇 2023-03-23
下一篇2023-03-23

发表评论

登录后才能评论

评论列表(0条)

    保存