也有一些云平台监控系统,多数是要收费,部署。
你把DS存储的管理口IP地址改成你们日常使用的网段,3650 M4服务器IMM也是修改IMM的IP,需要接入交换机,同一个局域网。这样你就能实时访问监控状态了。
HP的服务器在硬件管理方面提供了自己管理工具hpacucli,通过该工具可以查看HP服务器的RAID信息,服务器硬盘等信息。1)安装hpacucli工具(下载地址:HP hpacucli管理工具)
[root@monitor ~]#rpm -ivh hpacucli-9.40-12.0.x86_64.rpm
2)查看服务器RAID信息,硬盘是否正常。
[root@monitor~]# hpacucli ctrl all show config Smart Array P410i in Slot 0 (Embedded)(sn: 5001438018042FF0)array A (SAS, Unused Space: 0 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)
3)通过hpacucli ctrl all show config detail命令可以详细地查看RAID和硬盘的信息。
[root@monitor ~]# hpacucli ctrl all show config detail Smart Array P410i in Slot 0 (Embedded)Bus Interface: PCISlot: 0Serial Number: 5001438018042FF0Cache Serial Number: PBCDH0CRH1FH62RAID 6 (ADG) Status: DisabledController Status: OKChassis Slot:Hardware Revision: Rev CFirmware Version: 5.14Rebuild Priority: MediumExpand Priority: MediumSurface Scan Delay: 15 secsMonitor and Performance Delay: 60 minElevator Sort: EnabledDegraded Performance Optimization: DisabledInconsistency Repair Policy: DisabledPost Prompt Timeout: 0 secsCache Board Present: TrueCache Status: OKAccelerator Ratio: 25% Read / 75% WriteDrive Write Cache: DisabledTotal Cache Size: 512 MBNo-Battery Write Cache: DisabledCache Backup Power Source: CapacitorsBattery/Capacitor Count: 1Battery/Capacitor Status: OKSATA NCQ Supported: TrueArray: A Interface Type: SAS Unused Space: 0 MB Status: OK Logical Drive: 1 Size: 279.4 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Stripe Size: 128 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001034373220202020200002 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 99 MB Logical Drive Label: A00ADBD9PR7AMU1472 898D Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) Mirror Group 1: physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK) physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD4 Serial Number: ECA1PC80GTS31234 Model: HP EG0300FBDSP PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Rotational Speed: 10000 Firmware Revision: HPD7 Serial Number: PMX6902D Model: HP EG0300FBDBR PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown
HP官方还有一个hpasmcli管理工具,可以很详细查看服务器CPU,内存,处理器,电源等的温度信息。
这个和把大象关进冰箱里一样,需要3个步骤:打开机箱盖
机器加电
观察风扇是否正常转动
CMOS设置里可以看到风扇的转速和CPU温度,观察这些数值是否正常.
欢迎分享,转载请注明来源:夏雨云